Jds-uniphase WEB XPANDER RS-232 Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Hardware Jds-uniphase WEB XPANDER RS-232. JDS Uniphase WEB XPANDER RS-232 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Web Xpander
Installation and Operation
Manual
12200 Thatcher Court, Poway, CA 92064
TEL 858-486-8787 FAX 858-486-8789
www.jdstechnologies.com
Document Rev 1.4
February 2004
Vista de pagina 0
1 2 3 4 5 6 ... 33 34

Indice de contenidos

Pagina 1 - Web Xpander

Web Xpander Installation and Operation Manual 12200 Thatcher Court, Poway, CA 92064 TEL 858-486-8787 FAX 858-486-8789 ONLINEJDS

Pagina 2

DIGITAL ANALOG RELAY FLAG VARIABLE Type in or click Inc/Dec to adjust variable value then click “Load” to apply. Green “Clear” button indi

Pagina 3 - Installing the Web Xpander

TIMER ASCII HISTORY Click “Send” to issue ASCII data.

Pagina 5 - Network Configuration

SETTINGS Auto Page Refresh The Lighting, HVAC, X10, Digital, Analog, Relay, Flag, Variable, Timer, History, Msg Log and Tel Log menus each have a d

Pagina 6

Web Xpander Labeler The Web Xpander Labeler is a Windows utility that reads your device names from WinEVM and imports them into the Web Xpander. To

Pagina 7

Appendix A – Web Xpander Commands Command Description Example :reset= Resets the Web Xpander :reset= :factory= Load factory default values (follow w

Pagina 8 - Web Pages

:debug= Enables or disables debug information to be sent back through COM1 to WinEVM :debug=on :debug=off (default is off) :disable= Used to disable t

Pagina 9

Appendix B – Sending Email with the Web Xpander Sending email with the Web Xpander is accomplished by sending ASCII commands from the controller (i.e

Pagina 10

Appendix C – Managing a Dynamic Home Internet Address Accessing the Web Xpander from the internet (i.e. outside your home network) requires router sp

Pagina 11

Appendix D – Ethernet to Serial Bridge Functionality The Web Xpander provides a method of sending/receiving serial data to/from the STARGATE via the

Pagina 12

Web Xpander Programming Connector Stand-offsEthernet port to Network Router RS-232 Input from PC 12VDC Power Input Reset Button RS-232

Pagina 13

Appendix E – Downloading WinEVM Schedules over a Network Connection WinEVM has been successfully run over a network connection to the STARGATE using

Pagina 14 - Web Xpander Labeler

8. ** You must temporarily disable the username/password checking for remote access before connecting. Open the Settings page in your web browser an

Pagina 15

Appendix F – Performing a Firmware Update on the Web Xpander ** Note: This applies only to firmware versions prior to v1.6 July 16, 2003 (See App

Pagina 16

10-pin programming connector Properly attached Rabbit Programming Cable Using the Rabbit Field Utility 1. Start the Rabbit Field Utility located

Pagina 17

Firmware Utility Communications Options 6. From the main menu, select File, Load Flash Image 7. Click the button next to File Location and locate

Pagina 18

5. Select File, Transfer Web Page(s) from the main menu to transfer the web page(s) into the Web Xpander’s battery backed memory. This step is only

Pagina 19

Appendix G – Firmware Upgrades with the Network Download Utility The Web Xpander Network Download Utility is used to transfer firmware updates to the

Pagina 20

Appendix H – Internet Time Synchronization The Web Xpander can be configured to automatically synchronize your STARGATE's internal clock daily v

Pagina 21

Appendix I – Advanced WebXpander URL Commands One method of sending commands via the WebX web server interface is by simulating the functionality of

Pagina 22

Appendix J – Disabling the Web Xpander for Schedule Downloads and STARGATE Firmware Updates To disable the Web Xpander (prior to downloading), send t

Pagina 23

Welcome to Web Xpander Web Xpander is a serial (RS-232) to ethernet module with embedded web pages that allow monitoring and control of STARGATE vi

Pagina 24

Appendix K – Web Xpander Firmware Release History v1.0 26-Nov-2002 - Initial Release v1.1 1-Mar-2003 • Reduced the size of HTML pages by remov

Pagina 25

Example 1: sendcommand.cgi?var1=%23%23%2507&var2=str&var3=%23%230 %23 is the URL-encoded character ‘#’ and %25 is the URL-encoded character

Pagina 26

v1.3c 11-Jun-2003 • Removed sending CR to clear buffer before each command. Fixed problem reading time from TimeCommander+. v1.3d 17-Jun-2003 • Co

Pagina 27

v1.6d 3-Aug-2003 • Modified DHCP routines. WebX was correctly reading IP address but incorrectly reading and storing Gateway and DNS info. • Also

Pagina 28

v1.9b 24-Nov-2003 • Added serial command :debug=on and :debug=off to toggle sending debug information to MegaController of WinEVM (defaults to debug=

Pagina 29

Mounting to STARGATE-Lite (no Telephone/Voice Board) 3b. Using the supplied two standoffs that have screw holes on both sides, and two of the supplie

Pagina 30

3. Connection to a Cable/DSL Router This is the most ideal situation in that it allows you to access your STARGATE via the Web Xpander from your home

Pagina 31

Viewing Current Network Settings You can use the “:netinfo=” command to view the current network settings of the Web Xpander using WinEVM. From the

Pagina 32

If your Web Xpander is connected using network configurations 1 or 2 (above) you may need to manually set the IP address of the PC or the Web Xpander.

Pagina 33

:telnet= Sets the port (default = 23) for telnet (Ethernet to Serial) :telnet=23 :reset= Resets the Web Xpander :reset= :factory= Sets network values

Pagina 34

A/V Select Output then single click on the Name to send IR command. SECURITY Select security Command and Partition or Zone then click “Send Command

Comentarios a estos manuales

Sin comentarios